Release file version 6.03 Patch 01  (18/04/2002)
----------------------------------------------------------------
This document contains information on technical problems, corrections of 
known issues, limitations and new solutions.

	I- Corrections
	II- New Features



------------------------------
I- CORRECTIONS 
------------------------------


* It is now possible to save labels created under CS 3.60


******************
Barcode
******************
* Codabar barcode
  Human readable start and stop characters are now shown as upper case
  according to AIM Standards (on screen and printed).

* On a label with a Codablock A barcode, if you create it as the sample link
  and then select the barcode button and try to add another barcode,
  CODESOFT now continues to run normally (no longer stops working).

* The Lock function is now working correctly when used with a barcode
  and when the Human Readable is set to FREE.

******************
Formula
******************
* If the name of the label starts with a number, the following formula now returns a correct string length. 

  right(@LABNAME,11) 


******************
POF
******************  
* When generating a POF file, CODESOFT now uses the POC selected in the export menu.


******************
Printing
******************
* When opening the Printer dialog box, then clicking on Ok without changing the selected printer,
  you no longer lose the Specific Options for printers supporting this feature.


******************
Object
******************.
* The edit mode is now deactivated when you type text, click on the File menu,
  and then press escape to go back into the label.

* There is no longer a problem with inserting an EPS file.
  If the EPS file is not a raster image, the image is not displayed. 

* EPS files created by CODESOFT using the Export function are now in the right format
  and can be reused by other applications.

* Labels saved with 45 rotation of the display font can now be corrected under Windows 2000.

* The text now adjusts to be centered inside the frame with the fit to frame option.

* Improvements have been made for the continuity of the fit to frame option.

* When printing using Merge and using fit to frame, the frame now grows only if
  the smallest font is too big for the frame.


******************
OLE
******************
* Add an OLE object (like WordArt) to an empty label, then save the label.
  Open the label, move the object, and then save and close the label.
  Now when you reopen the label the OLE object is still there.

* The error "server application cannot be started" no longer appears when
  you are using the Insert OLE object function. 


**********************
ASCII Database
**********************
* There is no longer a problem with displaying data on a label with an
  ASCII database and the "Open merge database with labels" option checked.


************************
Database Manager
************************
* The function "Duplicate a Record" now creates a copy, not an empty record. 

* The control variables LABELCPY  and  SERIALQTY are now working under Database Manager.


******************
ActiveX
******************
* When using generate pof, with a file path for the poc file, 
  the file used is now the one indicated by the search path.

* When changing the value of a text object, 
  the font definition is now set to the first font used under CODESOFT.

* The date offset or offset type can now be read through ActiveX.

* Polygons are now printed correctly when labelling software is used as a hidden ActiveX.

* ActiveX early binding under VB with reference to TLB
  When accessing a variables.dates item you get the error:
  "function interface marked as restricted..."
  with late binding the dates property can be used without a problem
  syntax used:
  MsgBox cs.ActiveDocument.Variables.Dates.Item(1).Name
  Use DateTime Object name in place of Date.

* ActiveX Printdocument
  The Printdocument function now prints the linked document instead of the current document.

* ActiveX OpenODBC
  When closing the application you are prompted to save the query only if the server is visible.
  When closing a layout through ActiveX, or when quitting CODESOFT,
  and a label is open with a query, a message box, asking to register the query,
  appears behind the calling application window only if the server is visible.

* ActiveX-connection with ODBC datasource Oracle 8.1.7 in VB or
  ActiveX with attached database fields on SQL server
  When call OpenODBC method on the Database object use this syntax : "DSN=OraServ1;UID=username;PWD=password"
  Sometimes use UID or UserID entry name, depend of the ODBC driver
  DSN is the Data Source Name,
  UID / UserID is the User ID to login,
  PWD is the user Password.

* During a print job, events have been fired, precisely OLEPausePrinting,
  only if the server was visible. Now events will be fired in all cases, server visible or not.

* The quality of the CopyImageToFile and the CopyToClipboard functions has been improved.

* If the extension is specified, the CopyImageToFile function now creates the file with the extension.

* Changing the language through ActiveX now works correctly.

* When you use the OpenODBC call in CODESOFT's back end, 
  it returns a "true" if it actually makes an attachment to a table. 

* ViewOrientation now works correctly.

* When changing the text.VariableName of a text object or when the VariableObject is modified,
  the font definition is now set to the font of the text object.



******************
Settings
******************

* Additional serial ports will be completed from the registry entry. But, if they are not listed ,
  it is necessary to add ports manually from the panel configuration (start menu, parameters ) of NT4,
  then to select ports item, and to configure them and to restart the system.

* Label created with CODESOFT 4 containing a variable graphic - 
  If under CODESOFT 4 the path for the graphic is set to "another directory"
  as the default directory, this information is now retrieved when opening the label under CODESOFT 6.


******************
User Manager
******************
* It is now possible to list users of different domains under Windows NT and Windows 2000. 

* Under Windows NT/2000 User Manager now takes into account the login-sign space in the login. 

*There is no more problem with User Manager when using a local installation on Windows 2000

*************************
Batch Print Manager
*************************

* The Batch Print Manager now recognizes the field @LABNAME.


******************
Premier
******************
* When CODESOFT PREMIER is protected by a password, the use of the zoom button doesn't provoke an error anymore.

* Under Windows 98, the justification of the text field is now saved.

* When selected objects are aligned, the anchor point (top-left by default)
  of each object will be preserved for all products.


================================================================



----------------------------------------------------------------
Release file version 6.03  (10/11/2001)
----------------------------------------------------------------

This document contains information on technical problems, corrections of 
known issues, limitations and new solutions.

	I- Corrections
	II- New Features

--------------
I- CORRECTIONS 
--------------


******************
Image
******************

* Upgrading from 4.20 to Version 6.03 (Enterprise):
  The option " Adjust the size of the image" now works
  when the view of the label is rotated 90.


*****************
Database Manager
*****************

* Online help can now be accessed from Database Manager.

* A table where a field is a primary key (with Access ), 
  does not allow records to have the same value on this field. 
  This version of Database Manager does issue a warning to tell the duplicate record has not been
  added to the table.


******************
Formula
******************

* Two valid formulas are now imported with the correct double quotes when
  using a UFO file, as shown in the following example:
  Formula0: Formula="{FNC1}"
  Formula1: Formula= "1234" & Formula0 & "5678"

* When using variable with operator characters (ie : a+b ), in a formula, 
 if you click to add this variable in the expression, the format is {a+b} according to formula syntax.
 This should only happend if the variable name contain operators.

******************
POF
******************

* The model can be changed after selecting File - Export POF Object 
  Model <<mod.poc>>. A different POC can be used when generating a POF file.

* When File - Export as a Printer Object File (POF) is selected the POC 
  files are now listed even if Code Converter is not installed.


******************
Printing
******************

* The form display no longer shrinks when using the "Display form when printing" 
  option with the "For each label" option.


******************
Object
******************

* Lines are no longer shown beside an object when using 90 or 180 rotation of
  the display.

* When opening up a CODESOFT 5.04 label with CODESOFT 6.02.01 
1. The position of variable text (tt font) does not changed anymore
2. The text size does not changed anymore.




******************
Variable
******************

* A blank value is now displayed when you create a free variable, add it to the
  label in "Display field names" mode and then switch over to "Display field 
  contents" mode.


* There is no longer a problem with shadows and size of the image 
  when you do the following:
  Create a formula variable and use it as a graphic with the 
  "Proportionally adjust the size of the image" option activated, 
  rotate the whole label 180 or 270 degrees and then move the image. 
   

* An EAN13 EXT5 bar code is now visible on screen when you do the following:
  Create an EAN13 EXT5 bar code, enter -1 (narrow bar width i.e. 3 dots) in
  "Space correction" and then save the label and reopen it. 

* The following names can be used for variables:
STATUS, VARLIST, CLOSE, ERROR, PRINTERNAME
They were reserved names for the DDE connection. 
Because CODESOFT doesn't include DDE anymore, these names are available again.


******************
Printers
******************

* The printer-specific options are now saved when you edit the text 
  or when you set up the printer settings.


******************
ActiveX
******************

* Copyimagetofile now accepts values higher than 100. 


* ActiveX on table lookup fields
  To access the variable used as the search key by a table lookup variable:
  The return value is the concatenation of keys <strSearchField ,strSearchFieldValue>
  separated by coma.
  "{FIRSTNAME}={Var0},{NAME}={Var1}"

-------------------------------
II- New Features
-------------------------------

* Arabic, Hebrew, Russian and Turkish translations have been added 
  in this version.


* The EAN Assistant has been updated. 


* Database Manager: a warning message now appears when the 
  base format will be changed by:
  - Modifying the table structure 
  - Duplicating or changing the table name


* Formula: the Modulo10UPS function has been added.


***********
PRINTERS
***********

You will find, in CODESOFT installation folder, the files containing information 
on technical problems, corrections of known issues, and new solutions 
specifics to each printer driver.

 __________________________________________
Files   correspond to	Printers models
--------------------------------------
PAY.txt			Avery
PDX.txt			Datamax
PLPK.txt		Logopak
PSO.txt			Sato
PT.txt			Tec
PU.txt			Intermec
PZ.txt			Zebra



================================================================


----------------------------------------------------------------
Release file version 6.02.01  (07/16/2001)
----------------------------------------------------------------

This document contains information on technical problems, corrections of 
known issues, limitations and new solutions. 

	I - Corrections
	II - New Features

---------------
I - CORRECTIONS 
---------------


*********************************
VARIABLES
*********************************

* In the Form, after values are entered and the label is saved from the 
  Form display mode all values are now retained; the last entered value 
  no longer replaces the other values.

* If your variable image is in the default image folder, the image appears 
  when the document is opened.

*********************************
PRINTER/PRINTING
*********************************

* A graphic with a large white area or a polygon no longer has small
  dots in the white area when printed with a thermal printer.
  The problem has been corrected for all drivers since 05-23-01.

* Intermec EC 301 (in driver version PUDP.PRN 11.01.02)
  Direct Thermal setting of the printer driver is now saved and sent to 
  the printer.

* Intermec Driver, in Direct Protocol
  The command NEW SUPPLIES sent to printer models EC301 and E4 no longer 
  causes an error.
  The driver is based on firmware 2.0 and later.

* Microcom Driver
  The left side is no longer missing on all graphics sent to 
  400, 412 and 466 printers.

* Datamax Driver, all models
  It is now possible to include a check digit on Code 39 bar codes with 
   a Datamax printer selected.  (PDX.PRN version 11.01.12)

* Microcom Driver 
  Graphics are now printed on models 400 and 412 
  (in the PMC.prn version 11.01.04).

* Datamax I-class Driver
  Pound and Euro symbol are displayed on the screen in triumvirate, 
  but they are printed using the printer font "1."

* Zebra Driver 
  Printing with spooled access on a TCP/IP port is now working.

* TEC B30 Driver
  There is no longer a problem when printing a label with just 
  text in printer fonts.
  It is now possible to set the paper detection in the driver.

* OPTIMO 128, OPTIMO 150 and OPTIMO 250 Drivers
  When the paper is left positioned, the option "Adjust paper to the left" 
  is now available in the Advanced tab of the Printer Settings dialog box. 
  The margin does not need to be adjusted, the driver will calculate 
  the offset automatically.


*********************************
ACTIVEX
*********************************

* ActiveX bound method is now working correctly with fixed text:
  -- Bound method to modify text width works on text with only wordwrap set.
  -- With text set as fit to frame, it adapts the text to the frame.


******************
COMet
******************
* In the CS 6.02 Runtime version, an error message no longer 
  appears when starting COMet.


******************
Database Manager
******************
* In the Database Manager ME 6.01, there is no longer a problem when you
  try to print a selection using the "Select the records to print" dialog box.


*********************************
USER MANAGER
*********************************
* The functioning of CODESOFT is no longer affected when the User Manager is not
  installed.


******************
Sprint Version
******************
* The Form Customization function has been removed. 

-------------------------------
II - NEW FEATURES
-------------------------------

* The label stock formats TLS2200/TLS have been added for Brady printers.

================================================================

----------------------------------------------------------------
Release file version 6.02 (06/07/2001)
----------------------------------------------------------------


This document provides information about technical problems, corrections of 
known issues, limitations and solutions.

	I - Corrections
	II - New Features

---------------
I- CORRECTIONS 
---------------

*********************************
VARIABLES
*********************************

* If your variable image is in the default image folder, the image appears 
  when the document is first opened.

* It is now possible to type the characters (\, #, A, &, ?, U, L) in the 
  Form.

* In the Sprint version 5 and 6, the limits are now handled 
  (Reset the counter to 0 after 9999).

* The serial number is now saved automatically in the globvar.dat file.  
  Therefore, if anyone uses the shared variable, he can access the last 
  number printed.

* When creating a decreasing counter the error message indicating that the 
  counter is beyond the limits no longer appears.
 
* The values of the Table lookup variable are now saved in the Output tab of 
  the Properties dialog box. 
  It is now possible to define the maximum length of a Table lookup. If the 
  length of the data is longer than the length defined, the data is truncated.

* When Display form when printing is used, the window is initially centered on
  the screen; the last positioning or re-sizing of the form window is now saved.
 
* When using a FORM variable, the padding characters are activated when 
  the variable setup is reentered. 


*********************************
BAR CODES
*********************************

* When a graphic bar code is selected and then copied and pasted into Paint or
  PSP, a picture of a readable bar code is now produced. 


*********************************
PRINTER/PRINTING
*********************************

* When adding a printer to a TCP/IP address, the address is now saved when 
  the application is closed. 

* An error no longer occurs when printing a document that includes a 
  custom counter.

* UFO file: the bar code human readable is printed when the HRAuto parameter
  is set to 1.

* The list of variables now appears after a document is stored in 
  the Eltron printer.

* If you select a different printer, the Font list is correctly updated.

* It is now possible to select marked media with the Novexx Printers.

* Zebra printers now support the creation of oblique lines and circles.

* For Datamax I-4206, I-4212 and I-4308 printers it is now possible to 
  create the printer code 2D Datamatrix.

* During printing, objects are no longer printed several times on the same
  label.

* For the Novexx Lion printer, when printing from query preview or an 
  ActiveX application, the cutter is not activated if no cutter is selected.

* For the Easycoder 601 XP, the maximum narrow bar width is now 
  limited at 8 instead of 6 for the EAN 13 bar code.


*********************************
ACTIVEX
*********************************

* With CODESOFT in Automation mode and Application.EnableEvents set to TRUE,
  it is now possible to print on a THT printer.

* In ActiveX, after opening and closing several documents, a failure no 
  longer occurs at the opening.

* The Close, Quit and BeginPrinting events work correctly in this version.

* The CopyToClipboard method now recognizes the CF_DIB and CF_Bitmap formats.

* The ActiveDocument.Escape method works in this version.

* When using CODESOFT through ActiveX, it is now possible to see the error
  message if the dongle is not found.

* Unexpected closing no longer occurs when the Myapp.Application.Visible 
  method is used extensively.

* When printing a document that includes multiple labels on the same page,
  the labels will now print properly instead of all printing in the same
  label position on the page.

* If the object position is modified, the font sub-set is no longer affected.

* The Printer.send method is now working.


*********************************
POF Files
*********************************

* The %POFNAME% variable (located in the Process section of a POC File) 
  now sends the POF File path in the correct DOS format.


*********************************
VERSION COMPATIBILITY
*********************************

* A label created with an early version 4 or imported labels 
  are now saved with the correct file extension.

* When opening a document created with THT version 3.55, there is 
  no longer an object positioning problem.

* When opening a document created with version 4 that includes a
  Rectangle object, the Rectangle object now appears.

* It is now possible to save a document created with version 3.


*********************************
USER MANAGER
*********************************

* It is no longer possible to manipulate objects unless assigned 
  Add, Delete or Modify rights.


*********************************
DATABASE MANAGER
*********************************

* DATABASE MANAGER is launched in the language selected for CODESOFT.


*********************************
DONGLE
*********************************

* Some problems with recognition of the dongle have been solved for 
  the CODESOFT Network version.



-------------------------------
II - NEW FEATURES
-------------------------------

* The bar code human readable is now always centered in the Sprint version.

* The label stock formats LAT-41 to LAT-47, LAT-175 to LAT-178 and THT-101 
  to THT-105 have been added for Brady printers.

* Dataman ME replaces the Database Manager 98 and 2000 applications.

* The TLC 39 bar code, a composite bar code developed for the 
  telecommunications industry, has been added. This code serves as a
  transition between the Code 39 symbology and the future Micro PDF 417
  bidimensional code.


================================================================

----------------------------------------------------------------
Release file Version 6.01  (01/02/2001)
----------------------------------------------------------------

This document provides information about technical problems, corrections 
of known issues, limitations and solutions.

	I - Corrections
	II - New Features

---------------
I - CORRECTIONS 
---------------

  - Polish prompts are now included.
  - The application runs in the language selected during installation.


*********************************
 Open/Import Documents
*********************************

* A fatal error no longer occurs if two documents are open, you save the 
  first document when exiting, and then attempt to save the second document
  with the same name as the first document.


*********************************
Text Objects
*********************************

* Subset management has been corrected: 
-- The list of subsets is now available all the time. 
-- If you selected a subset, it is not kept the following times 
   you access the text settings.


*********************************
OLE Objects
*********************************

* A fatal error no longer occurs if you select the command Links from the Edit
  menu after deleting a linked OLE object.

* Paste Special now works properly if text is pasted from a Microsoft Word
  document.


*********************************
Printer Management
*********************************

* The default bar code is now printer and not graphic for THT printers.


*********************************
Printing Management
*********************************

* It is now possible to directly access the Printer settings dialog box 
  by pressing F6 and then F5. 


*********************************
Image Management
*********************************

* The Image Properties dialog contains a link to the image file. If the file
  does not exist on your computer a complete message is displayed; previously
  the message was blank.

* When an image is added to a document and then you double click on it to
  change it to a second image, the image file name is updated. If you double
  click on the image again, the second file name is now retained. Previously,
  the first image file name would reappear.

* Images in WPG format are compatible with this version.

* It is now possible to change an image to monochrome mode.


*********************************
ODBC and Linked Tables
*********************************

* If a new query is created in a document and variable fields from this 
  query are placed on the label and the document is saved but not the query,
  when the document is reopened and the query is edited, if Cancel is selected
  the list of fields is now displayed in the ODBC query definition dialog.


*********************************
Variable Management
*********************************

* In the SPRINT version, when a variable date is added to a label as a text
  object in value mode it is now displayed.

* German Help text for formula functions in the Formula dialog box is 
  now complete (i.e. AND, IF, and many others).

* In the Formula dialog box the Help text for day-function is now mapped to 
  the correct topic.

* The option "Save the last values of variables" (only available in 
  the RunTime version) now works correctly.

* The input format * is now working.


*********************************
OLE Interface
*********************************

* When using the OLE V1 interface the Variables.showFiller no longer generates
  an Automation Error and the form is displayed.

* When using the OLE interface the prompt property is set when a variable is
  created. 

* If Internet Explorer 5 is installed on your computer, CS6 running with 
  an OLE interface no longer crashes after the "Quit" function.

* The size of a text object is no longer incorrect if it is rotated.

* Previously, if you added a text object like "Hello" (ll as Italic), only an
  object containing "o" was returned. This no longer occurs.

* Object collections now return the proper line type. For example, if it was: 
    image.type = 3
    line.type = 3
  "4" will now appear as the line.type.

* It is now possible to delete a bar code object and create another one 
  with the same name.


*********************************
Other
*********************************

* When you select 2 text objects and change the font using the toolbar 
  and then undo the action, the font settings are now recovered.

* It is now possible to edit in the Default folders tab (Options 
  dialog box).

* The Demo version (without a dongle connected), is always checking for 
  the dongle. The result of this is that each action is very slow.

* When an oblique line is selected, if you display the Position/size dialog box 
  and you click on OK without changing the values, the line position is no 
  longer moved.

* On-screen rotation of a document no longer makes the horizontal and vertical
  lines disappear (rotation of 90 and 270 only).


*********************************
Tools
*********************************

* EAN 128 Assistant: if you select the Cancel button an error message
  is no longer displayed.

* Font Downloader: the display font of CODESOFT is now used in Font Downloader.

* Font Downloader: it is now possible to select a printer connected to a TCP/IP
  port.

* COMet: the translations are now correct for the double bit platforms. 


*********************************
Printer Drivers
*********************************

* TEC Drivers
  It is now possible to display and edit the TEC printers setting.

* TCP/IP
  - Main functionality corrected.
  - Synchronism is correctly respected.
  
* PRINTRONIX Drivers
  - WIDTH parameter of the PAPER command is correctly specified. 
  - T5x06 is now specified as 6.6".

* ZEBRA Drivers
  DA402 now has a valid scalable font.

* INTERMEC Drivers
  EasyCoder C4 now has the minimum label gap for gapped labels set at
  15 dots instead of 13.



-------------------------------
II - NEW FEATURES
-------------------------------

* IP address customization:
  The IP address by default is 9100.
  To change this value, add the following sentence in the [GENERAL] section
  of the CS.INI:

  IPPPortNumber= (enter the correct value)


*********************************
Printer Drivers
*********************************

* ALLEN
  Added a new driver with 3 models:
  - Allen TT107IM
  - Allen TT53IM
  - Allen TT85IM

* NOVEXX
  The number of paper types has increased from 2 to 4.

* ZEBRA
  The "Adjust origin vertical" option (^LT command) was added for XiIII models.