Version 4.10B Patch 3
------------------------------------------------------------------------------------
  - After a 'Test print', global import variables did not restart with their initial value.
  - DDE: During a DDE merge using a PRINTQTY field, the value of this variable was ignored.
  - All network ports are now visible from the printer connection box.
  - DDE: The SetPrinter function could fail in selecting a printer/port couple.
  - UFO file: In the variable section, the "repeat" section was not correctly read.
  - Trying to align an empty text variable with other objects did not work.
  - ASCII Import: Characters with ASCII code >126 could not be used as fields separator.
  - Date Variables: The numbers added to dates were limited to -3600 for days and -120 for
    months. Now, these limits are -9999 and +9999 for days and months, -99999 and +99999
    for minutes. A GPF occurred if the calculated date was later than 31/12/2037.
  - Date variables: Adding a variable to a date the program could pick the wrong variable 
    If 2 variables had names starting with the same characters (ABCD and ABCD2).
  - Computer dates (not printer dates) were not reevaluated during printing. Now they are
    if a variable is added to the date. 
  - Formula variables: The formula if(-2 < -3, "True", "False") returned True.
  - Using LABNAME field in a database merge the program did not produce any error 
    message when the label did not exist.
  - It was not possible to use the delete key in the filler when a format was set in the
    Import field.
  - Closing a modified label that had been opened in 'read only' mode did not produce a 
    "save ?" message.
  - Global variables: 
    - If the path to globvar.dat file was a long file name, the timeout message was displayed.
    - Some access conflicts during network printing have been corrected.
  - Under windows 3.1x, the number of page copy was not taken into account when printing 
    through Windows driver.
  - Formula: The char(num) function did not work correctly if num was greater than 126.
  - Formula: The Text(Value, Format) function did not work correctly if Format used ".".
  - If the maximum length of a variable was set greater than 32767, it caused a GPF.
  - Reading a label that uses resident fonts or barcodes on a driver that had none caused a GPF.
  - Opening a database having a LABNAME field did not automatically open the correct label file.
  - Database Manager: Creating a new database under the name of an existing database destroyed
    The existing database, even if the user cancelled the creation.
  - Database Manager: Data containing quotes (") were not printed when doing a merge print.
  - If all records from a database were deleted the last record was still printed in an ODBC
    merge.
  - Display of graphical code 39 did not show any difference between ratio 2 and 2.3 
  - UCC/EAN assistant: Could not be run if the program was not installed in a subdirectory.

Printers:
---------
  - New printer driver Datamax Titan 6200
  - New printer driver Open Date Thermocode 5775
  - New printer driver Monarch 9835
  - New printer driver Z4000, Z6000, Zebra 172PAX LH, Zebra 172PAX RH, Zebra 173PAX LH, Zebra 173PAX RH

Eltron
  - New option to add the printer settings in the label format.
  - Peel Off functionality has been inverted like it is on the printer.
Datamax
  - New option to mirror the printout.
  - New option to add memory for scalable fonts in the printer settings.
  - The "cut last piece" option has been improved when printing with variable fields. 
Intermec
  - It is now possible to send immediate settings even if the printer is not directly connected 
    to the port.
  - It is now possible to use a non standard protocol (ex: "STX" instead of STX character).
Sato
  - New option to cut at the end of the batch.
  - It is now possible to send immediate settings even if the printer is not directly connected 
    to the port.
Tec
  - New option to use the CC200 security level in the resident Datamatrix barcode.
  - Maxicode now available.
  - New option to use the COPY mode for graphics (default mode is INVERT).
  - It is now possible to use the Fast Graphics on the TEC B30.
Ubi Direct Protocol
  - The size of the downloaded fonts is now WYSWYG.
  - The internal printer fonts on EasyCoder 101/201/401/501/601 are now printed.
Zebra
  - Maxicode now available.
  - Datamatrix now available (firmware 18.7.1 or greater).
  - The printing of inverted graphic text has been corrected.


------------------------------------------------------------------------------------
Version 4.10B Patch 1
------------------------------------------------------------------------------------
  - Two new code converters for Intermec and Sato files.
  - The selection of a network port for a printer is now selective (under Windows For
    Workgroups, 95, NT) avoiding long waits on large networks.
  - Three new DDE functions have been added to handle merge databases: ConnectDB,
    DisconnectDB, Merge (Read LAST-DDE.TXT in the SMPDDE directory).
  - It is now possible to specify the port of the electronic key in de file CS.INI,
    section [General], Keyport = 1, 2, 3 for LPT1, LPT2, LPT3, allowing to use an 
    other application that is protected by the same kind of key.
  - The question "Do you want to save the label ?" is now asked when you quit the
    program after modifying a variable value.
  - Under Windows 3.1 it was not possible to set the COM ports to "No flow control".
    Corrected.
  - Wrong translation of "October" in Hungarian. Corrected.
  - UFO reading now checks for max variable length validity, printer dates,
    commentary in label format and database connection.
  - Trying to open a non-existent file used to create a zero length file: Corrected.
  - The LAB file extension was not added automatically to the file name when saving:
    Corrected
  - A white space character was added at the beginning of the lines of a paragraph
    (except on the first line) if the lines started by a variable field: Corrected.
  - A new flag named "stretchmode" is available in the CS.INI file, in the [images]
    section. When set to 1, the size reduction of an image will privilege the white 
    dots. By default the program privileges the black dots.
  - Error in coding Codabloc F: Corrected.
  - The system variable @LABNAME could not be set to a name with spaces: Corrected.
  - In LITE 4 there was an error in calculating the max length of combined field:
    Corrected.
  - The "@" input format of an import field did not allow uppercase characters:
    Corrected.
  - The "pop up" filler now puts automatically the cursor on a line where there is a
    wrong input value
  - The font download module did not work correctly in Windows 3.1: Corrected.
  - The program crashed in NT4 when a network Windows printer was selected without a
    local printer being created first: Corrected.

Printers:
---------
  - New printer driver RHS Alpha
  - New printer driver WilluxPrint Codlux
  - New printer driver TTF Megabu
  - New printer driver Novexx Xtreme
  - New printer driver Barcode Blaster BD242005, BD422005, BT242004, BT422004, BT423002
  - New printer driver UBI 301, 501 XP, 601 XP and direct protocol
  - New printer driver Printronix T2204
  - New printer driver Datamax Allegro 2 and Ovation
  - The printers that can do it now calculate alphabetical counters.
  - The printers that can do it now calculate counters with multiple quantities
    between incrementations.
Eltron
  - It was not possible to set the number of lines of a PDF417 barcode: Corrected.
Astromed
  - The "wysiwyg" of the barcode human readable has been improved.
Novexx
  - It was not possible to cancel the "double cut" once activated : Corrected.
  - A merge with variable graphics could saturate the printer memory: Corrected.
Datamax
  - On Max 300dpi the position of objects is totally accurate now.
Intermec
  -  "wysiwyg" has been improved for PDF 417.
  - In some cases printing an image could generate a "Range Error 2": Corrected.
  - Monospace fonts have been integrated in 4630 and 4830.
Monarch
  - Graphics are now sent after the other data on 9820 and 9830 and print correctly.
  - Possibility to cut at the end of a batch has been added on 9425, 9445, 9465and
    9474.
Sato
  - "wysiwyg" has been improved for PDF 417.
  - The management of images downloaded to the memory card have been improved.
Zebra
  - The font downloader did not work with Zebra printers: Corrected.
  - The print speed of 2'/sec has been added on XII